Electrical Installation Level IV — practical prep

የኤሌክትሪክ ጭነት ደረጃ IV — ተግባራዊ ዝግጅት

Directive 912/2014: L4 theory is 80 MCQ / 55%. Practical must meet 100% of the centre's criteria. Isolation and PPE are not optional.

  1. Read a small dwelling or kiosk brief and sketch a circuit schedule

    Tools

    Drawing · Calculator · Cable tables the centre provides

    What assessors typically watch

    • Lighting, sockets and a dedicated load are split
    • Protective-device ratings and conductor sizes are written
    • You can point to earthing / RCD on the sketch
  2. Terminate and identify a PE, a neutral, and a phase on a board

    Tools

    Strippers · Ferrules if provided · Earth bar

    What assessors typically watch

    • Green-and-yellow is PE and lands on the earth bar
    • Strain relief is on the sheath
    • You do not mix N and PE on a TT board

    Safety: Prove dead if the board can be energised. No live work without a permit.

  3. Select an MCB/RCD pair for a socket circuit from a given In/Iz

    Tools

    Breaker samples or a chart

    What assessors typically watch

    • Ib ≤ In ≤ Iz is stated
    • 30 mA RCD is chosen for personnel sockets unless the brief says otherwise
  4. Walk a fault: dead socket, lamp out, or an RCD trip on a trainer

    Tools

    Multimeter · Lock-out if live

    What assessors typically watch

    • You measure before you replace
    • You restore and prove the circuit
    • You log the fault in one sentence

    Safety: Lock-out / tag-out. Never 'bypass the RCD to finish'.

  5. Mount a small board or tray so it can be inspected

    Tools

    Fixings · Level · PPE

    What assessors typically watch

    • Fixings match the wall
    • Cables are supported, not hanging on terminals
    • Covers go back on
  6. Handover note: circuit chart, test tick-boxes, leftover materials

    Tools

    Paper or editor

    What assessors typically watch

    • A second electrician could find each circuit
    • Waste copper / offcuts are listed for recycle, not dumped

Bring

  • Closed-toe shoes
  • Non-programmable calculator you have practised with

Do not

  • Do not energise a circuit you have not proven
  • Do not bring leaked exam photocopies into the centre

Original Abrari wording. This is not an official assessment tool, occupational standard, or TTLM. Assessors follow the national OS and the centre's instruments — use this only as a study checklist.